IPSIndian Journal of Pharmacology
Home  IPS  Feedback Subscribe Top cited articles Login 
Users Online : 902 
Small font sizeDefault font sizeIncrease font size
Navigate Here
 »   Next article
 »   Previous article
 »   Table of Contents

Resource Links
 »   Similar in PUBMED
 »  Search Pubmed for
 »  Search in Google Scholar for
 »Related articles
 »   Citation Manager
 »   Access Statistics
 »   Reader Comments
 »   Email Alert *
 »   Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3166    
    Printed314    
    Emailed2    
    PDF Downloaded309    
    Comments [Add]    

Recommend this journal

 

 RESEARCH PAPER
Year : 1997  |  Volume : 29  |  Issue : 3  |  Page : 168-172

Reduced toxicity and enhanced antitumor efficacy of plumbagin using poly (Lactic-co-glycolic) biodegradable injectable implant



Correspondence Address:
U V Singh


Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions

Objective: To prepare poly (lactic-co-glycolic) acid (PLGA) injectable gel implant for the delivery of plumbagin (PLB) to reduce the toxicity and enhance the antitumour efficacy. Method: PLGA was dissolved in triacetin and PLB was dissolved in this. A gel matrix was formed immediately on contact with aqueous fluid. In vitro release studies were carried out in phosphate buffered saline pH 7.4. Acute toxicity studies were performed in normal BALB/c mice and antitumour efficacy in BALB/c mice bearing Sarcoma-180 tumour. LD50 and volume doubling time (VDT) values for plain PLB and gel implant injection was found after subcutaneous injection. Results: In vitro release of PLB was observed for a week. It was dependent on the concentration of PLGA used. The LD50 for plain PLB and gel Implant was found to be 8.60 mg/kg and 9.33 mg/kg. VDT for plain PLB and gel implant was found to be 6.5ñ 0.9 days and 11.5 ñ 0.5 days respectively. Conclusion: The toxicity of PLB was reduced in mice after subcutaneous injection of the gel containing PLB compared to plain PLB. The VDT was significantly higher for the gel compared to plain PLB. Thus the gel implant could be an effective drug delivery system for reducing toxicity and enhancing the therapeutic efficacy of PLB.






[PDF]*


        
Print this article     Email this article

Site Map | Home | Contact Us | Feedback | Copyright and Disclaimer | Privacy Notice
Online since 20th July '04
Published by Wolters Kluwer - Medknow